Thanks  for purchasing the products of Beautopia.

§ Please, keep a followed directions, and acknowledge this guidebook properly before using.
§ Put this book near to the machine.
§ At the book, there are many directions to use products of Beautopia, and it can help use the products much properly.
§ Please keep the following directions.
§ Out of order (unusual)

 

When any smoke or strange smell goes up, please turn off the main power switch and pull out the AC adapter.

If there is any smoke or strange smell, please turn off the main power switch and pull out the power plug.

If any moisture and alien substance are inserted the inside of machine, turn off the power switch and plug off.

When the machine fall down on the floor, turn off the power switch and plug off.

If the power plug is damaged & the machine generates heat, please turn off the power switch and plug off immediately. If you leave a machine as it is, it causes a fire or an electric shock.

Please call Beautopia Co. Ltd agency, if the machine has any problems.

 

 

 

 

 § Installation

 

Install a safe and well ventilated place on a horizonal plane.

Keep the machine out of the direct rays of the sun.

Do not put the machine in high temperature and airtight place. above of all, it can cause transformation and damage near the heater. Avoid the dust, smoke, moisture and oily things with the machine.

When you move the machine to another place, please plug off and separate all coupling devices.

 

 

§ Use

 

Do not repair, remodeling and disassembly. High voltage can cause a fire or an electric shock in the machine.

Please call Beautopia Co. Ltd agency, if you need any helps.

Do not insert an alien substances. It can cause an electric shock.

(Keep out of reach for children.)

Avoid damaging the plug, pulling the cables, putting a heavy things on the machine.

Please turn off the power switch and plug off in the thunder & lightning weather conditions.

When you pull out the plug, do not grip and pull the cable.

Do not grip a the plug with wet hand.

If you don't need to use the machine for a long time, plug off is recommended.

Be careful keeping a magnetic things next to the machine. It causes an out of order.

No insectcide.

Do not dust to the machine with insectcide and volatile solvent. It can causes a discoloration.

It recommend to smooth a stain pots with smooth rag.

 

 

§ Diagnosis of disorder

 

symptoms

managements

Out of power

¨ç power switch on backside : -,0 check

¨è compressor switch on the back of body : -,0 check

¨é Check a connection between front and base of body.

Disorder of accessories

¨ç Check a connecting cable's location on the backside.

Disorder of Airbrush

¨ç Check a connection of body's right + Airbrush hose + Airbrush

 

 

 § Standard

 

 

Scalpmaster

Size(WXDXH)

470 × 400 × 950(mm)

Weight

29.5kg

Power supply

AC 220V, 60Hz

Power consumption

20W

License No.

No.06-580

Patent application No.

No.2007-1002

 

 

 § Accessories
1. Scalpscrubber
2. Iontophoresis : Ion handle , Ion earth
3. Ultrasound massager
4. Airbrush
5. Airbrush hose
6. Electric cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1) Head (main operation)

 

 

2) Body

 

 

3) Scalp scrubber

 

 

4) Iontophoresis

 

 

 

<Ion handle>

<Ion earth(ground cable)>

 

 

5) Ultrasound massager

 

 

<For scalp>

<for face>

 

 

6) Airbrush

 

 

7) Airbrush hose

 

 

8) Electric cable

 

 

 

 

1) Head (front operation part)

 

 

 

01. Scrubber time regulator : Setting a operative time by the 5 minutes. (maximum 20 minutes)

02. Ultrasound time regulator : Setting a operative time by the 5 minutes. (maximum 20 minutes)

03. Ion time regulator : Setting a operative time by the 5 minutes. (maximum 20 minutes)

04. Scrubber intensity regulator : Setting an intensity of scrubber as low, medium and high level

05. Scrubber start/pause button

06. Scaling optional button : The optional button to choose a scaling function of scrubber

07. Toning optional button : The optional button to choose a toning function of scrubber

08. Massager optional button : the optional button to choose a massager function of scrubber.

09. Ultrasound start/pause button : It's a button to operate an ultrasound for scalp and face.

10. Ultrasound optional button for scalp

11. Ultrasound optional button for face

12. Ultrasound intensity regulator : Setting an intensity of ultrasound as low, medium and high level.

13. Iontophoresis start/stop button

14. Iontophoresis (-)Ion optional button

15. Iontophoresis (+)Ion optional button

16. Iontophoresis intensity regulator : Setting an intensity of an Iontophoresis as low, medium and high level.

 

 

 

2) Connection terminal in backside

 

 

 

01. Uultrasound for scalp

02. Ultrasound for face

03. Iontophoresis for Ion handle

04. Iontophoresis for Ion earth(ground cable)

05. Scalp scrubber

 

 

 

 

 

1) Head + Body

 

 

2) Head + Terminal

 

 

3) Body + Airbrush

 

 

 

 

 

 

 

 

 

 

 

 

 

1) Scalp scrubber
¨ç Cleansing, Sterilizing : Apply the probe with supersonic frequency vibration, it will vaporize the cleansing water liquid rapidly to emulsify the oil dirts, dust dirts, remove dead skin cell & black-head, improve pimple and resolve pigmentation, cleanse and sterilize. Cleansing procedure is safe, effective and comfortable.
¨è Scaling : Ultrasonic frequency vibration to mist cleansing water liquid, it will immediately soften the expanded pores, peel off , strengthen scalp activation.
¨é Toning : It helps permeate nutritional amples into into scalp with a vibration of ultrasound.
¨ê Massager : It makes scalp energetic by following (+), (-) ion with a vibration of ultrasound.

 

 

2) Iontophoresis

It is used to facilitate the penetration of ionized forms of the nutrients. As a result of penetration, this program makes the scalp & hair healthier and more beautiful.


¨ç (-) Ion
Activates and regenerates scalp & hair, penetrates of regenerating cosmetic substances into the lower layers of the dermis. Treats a discoloration, Freckles and pigmentation with penetrating ionized Vitamin C to the pigments in the deeper scalp.
¨è (+) Ion
Pacifies the scalp & hair, contracts skin pores and especially effects in improving pimples and acne.

 

 

3) Ultrasound System
¨ç Continue function
- Continuous 1Mhz ultrasound makes scalp & hair activative.
¨è Pulse function
- Pulsed 1Mhz ultrasound is used to penetrate fluids for synthesis of nutritions similar to an elastin. Delicate massage system makes cells activative.

 

 

4) Airbrush
Airbrush helps penetrate fluids of coditioner & treatment to transform them into small particles.

 

 

 

 

 